D1 - SYSTEM - EXP
Waterproofing of intermediate floors
CE Marking / Technical Approval | BILAYER ELASTOPHENE® FLAM / SOPRALENE® FLAM | ||
---|---|---|---|
BILAYER SBS SYSTEM | |||
2nd layer | |||
1st layer | |||
Total thickness | 5.5 mm | ||
Performance | F 5 I 5 T 4 |
Soprema advices:
- Increased acoustic properties according to the technical Guideline: for SOPRALENE® under tiles with VELAPHONE® CONFORT.
- Possible to use adhesive mortar and tiles directly on plaster-based boards, according to technical agreements. ELASTOPHENE®FLAM / SOPRALENE® FLAM or ALSAN® 410 solvent free liquid waterproofing system.
website.guides.summary
- TYPE OF WORK Intermediate floors
- TYPE OF PROJECT Wet rooms under tiles
- SUBSTRATE Reinforced concrete substrate
- THERMAL INSULATION Without insulation
- SLOPE 1,5 - 5%